Energy saving in industrial processes |
n5o10 edited 29.04.2023 | copyright by |
|
If services or offers from third parties or standards are obtained, no guarantee can be given for the correctness of the information at the present time.
The preparation of hot water for process purposes is one of the most common concerns in industry. This requires a lot of energy. As a first example, we show how this task can be solved with the means of solar thermal energy:

Energy saving using Solar thermal solution
According to the value determined for the solar factor for the exact location and the technical parameters of the solar system (see section "Solar Assistance" of this website), approx. 80% of the energy required for heating per year can be generated free of charge from the sun (example: Johannesburg).
Other solutions: to say it right in advance: when we talk about energy savings we are not talking about replacing incandescent lamps with LEDs when we are talking about energy savings in the industrial manufacturing process. We are talking about process-related energy requirements and one has to be able to calculate this.
|
heat recovery
not good ! |
In the picture we see individual processes, each of which has its own energy supply and therefore also its own removal of the residual energy in the form of heat, which is conducted into the environment.We often find this scenario in older systems, but also in new systems.
|
|
|
There are two main reasons for this: 1) The processes were built at different times and / or by different manufacturers. 2) It is a sin of the purchasing department. Purchasing departments often only have prices for individual subsystems in their heads and do not have an overall technical understanding. They have a tendency to break down whole things into parts that are easier for them to understand. Tenders are then issued for these subsystems and the cheapest provider is awarded the contract. |
The provider, in turn, has to completely fulfill his sub-process and accordingly offers it with its own energy supply and its own disposal of the residual energy. He cannot do otherwise because he only knows his own sub-process.The problem in all of these cases is that there is no overall technical planning that also takes energy issues into account.
However, it is not uncommon for such omissions to be repaired, even in old systems, if an on-site energy consultant carries out an analysis and suggests modifications. It is not uncommon for the problem to be solved with an investment that pays for itself after half a year to a year. After this short time for the return of investment, costs are saved permanently.
An example: we are talking about industrial plants that run in 3 shifts, i.e. 24 hours a day. For 350 production days per year, there are 8,400 production hours per year. We are assuming a low value of only 50 kWh, which we could save per hour. This is little for industrial conditions. With an assumed gas price of 0.75 Rand / kWh, 50 kWh/h of saving has a potential savings of around 300,000 Rand per year.
So we want to save the energy that is channeled through the exhaust chimneys into the environment and lost by the individual processes. How do we do that ?
The next picture shows the solution:
|
Problem solved
|
|
|
Here we see that the excess energy from the warmer processes is fed to the respective colder processes for energy supply. Therefore, the total energy used is optimally used. Often only small conversions that are inexpensive are sufficient. |
A really big energy saver is the use of a heat pump wherever the task is drying:
|
Case: adhesive water dryer in conventional design |
Case: adhesive water dryer designed as a condenser dryer |
|
|
|
|
Drying works mainly with dry air = air without water and ventilation. The measure for the water content in the air is the relative humidity. In the case of the conventional dryer, the relative humidity is lowered by heating the moist air => heating costs energy. Open process: as the picture shows, this energy is lost with the exhaust air flow into the environment. In the example we assume that we need an output of 6 kW for drying of this type. |
A heat pump has a motor that drives it. It has a cold side and a warm side, just like an air conditioner. If we cool the air to 2 ° C on the cold side, this causes the vaporous water contained in the air to be converted into (demineralized) liquid water. The relative humidity drops to 0%. This absolutely dry air dries very well! Now the miracle happens: on the warm side, the heat pump produces energy, approximately 5 times the drive energy used. If we use an output of 1 kW to drive the heat pump, then in addition to the absolutely dry air, we get approx. 1 ltr. demineralized water per KW and hour 6 kW of thermal power, which is available for other processes. The reason for this is the enthalpy of evaporation of the water (this is the energy that is required for the evaporation of water), which is released again when it becomes liquid. Compared to the conventional process, not only have we not lost any energy, we have even gained five times as much energy! And we have a closed stable process that is independent of the environment. |
Combined solutions
Now we take these single solutions together in the (re-)construction of an industry plan. Instead of planing single processes like this ....

... we better do it like this:

We clearly see that the drying process with the heating pump feeds the other 3 processes and we end up with just one exhaust with rest energy.
Note: it is of course not enough to just look at the temperatures of the processes. Of course, it is also about volume flows and masses. The mass of the workpieces must also be included in the thermodynamic calculations.
We can calculate such process chains!