Solar assistance is the percentage contribution that a solar system can contribute to energy production at a location.

Our services
We create expertises for each location and calculate the solar factor, which states what percentage of the technically installed energy production can be achieved by the solar system.
This does not distinguish between solar thermal solutions and photovoltaics.
This all applies for all ranges of energy usage, household as well as big powerplants or industrial purposes.
Technical background
|
Solar Assistance |
Usable energy can be obtained from the solar radiation of the sun, namely either high-quality electrical energy or heat energy. The belief that "energy production" would always be equated with electricity production is wrong, as the thermal needs -if they exist- often excced the electrical needs in energy. |
|
Photovoltaik |
Photovoltaik (PV) creates electrical DC energy from solar radiation, using silicium crystals. |
|
Solarthermie |
Solarthermie collectors absorb the solar radiation and convert it directly into hot water. Usually a temperature range of 60-70 °C is reached, but 130-150 °C are feasible as well. |
|
Common basis:
Solar radiation upon a location
|
The energy source
common to both technologies is the solar radiation P solar
[W/m2] incident on the surfaces of the collectors. The strength
of this radiation depends on various factors. And it is not constant in
one place either
|
|
How solar calculation works If a technical output power P tech is installed in the form of a certain solar area of the collectors in m2, then this installed output corresponds to the maximum expected output P max [kWp] of this installation: P peak [kWp] = P tech max. In the case of non-tracking systems (which is usually the case), the influence of the sine curve over the day must be taken into account. The average value of the power P [kW] results as P [kW] = 0,67 x P peak [kWp]. This figure corresponds to the average output over a solar day.
|
|
|
Energy E max
per day per year |
If we multiply the average power P [kW] by t = 8h solar time per day ("solar day"), we get the energy E produced by the solar system on a day as E 8h = E 24h = P x 8h = P peak x 0, 67 x 8h in [kWh]. The annual production of the solar energy system results directly from this
E max p.a. = 365 x E 8h as the maximum value that can be expected. However, it is known that this value will never be reached due to bad weather. It is therefore a theoretical maximum value E max pa. |
|
|
|
|
In this way, the maximum technically possible value E max of the annual energy production of a plant is obtained, but not the value that it can actually deliver at a specific location under the influence of the influencing factors mentioned above. The real value E real is required. |
|
|
Energy E real (real value) |
The calculation programs we use make the same calculation, but have also saved the worldwide weather data for years for every location worldwide: If we enter all the technical data of the system (installed power, exact location, orientation of the system to the south or north, the roof angle, other influences) into the calculation programs we use, the programs calculate the real value of the power that the system will deliver. (at least as an expected value) |
|
Solar factor |
The calculation programs we use make basicly the same calculation, but have also saved the worldwide weather data for years for every location worldwide: If we enter all the technical data of the system (installed power, exact location, orientation of the system to the south or north, the roof angle, other influences) into the calculation programs we use, the programs calculate the real value of the power that the system will deliver. (at least as an expected value) The maximum possible value E max always directly results from the technical dimensioning of a system, this is automatically the case. If you put the value E max in relation to the real value E real obtained from the special programs, i.e. form a quotient Solar factor [%] = E real / E max then we get what we call the solar factor. It indicates what percentage of the installed power capacity or better energy expectation the system can actually deliver. |
|
Evaluation Energy saving |
The example shows a 10 kWp solar installation in Johannesburg with the input data shown. It turns out that for this location, 84% of the energy production that is technically possible for the plant is achieved as an annual value. At a location in Düsseldorf in Germany, for comparison, 60% can be expected. Basically the results say that on 40% or 16% of the days of the year either the irradiance angles are too flat (location factor) or the weather is too bad. The flat angle of the radiation could be compensated by increasing the solar surface, the bad weather could not. Under the condition that a solar system is technically designed for 100% of the demand, this means that according to the solar factor we determined, 60% (Düsseldorf) or 84% (Johannesburg) of the energy demand is generated for free.
|